What's new in version 2604.0.0.0

Quality Control (BC)  •  Release Note  •  10/21/2026  • 

The Change Status button in the Quality Control App requires the Aptean Status Management extension, version 2603.0.0.0 or later, and a certified status flow for quality control checks. The other changes in this release do not depend on the Aptean Status Management extension.

Features

With the features added in this release of the Aptean Quality Control (BC) extension,

  • The status management status of an unposted quality control check can be changed directly in the Quality Control App. When the Aptean Status Management extension is licensed and a certified status flow exists for quality control checks, the Change Status button appears on the check and opens the Change Status dialog, which shows the current status and lists the statuses the check can move to. A status that requires a permission role the user is not assigned, or that would skip a mandatory status, is greyed out with a tooltip that explains why. The same rules are checked again in Business Central when the change is confirmed; if the change is rejected, the error is shown in the dialog and the status is not changed. The button is hidden on posted checks and when the Aptean Status Management extension is not in use. For more information, see Change the status management status.

  • Posted quality control results can be analyzed across checks on the new Quality Control Data Analysis page, which shows one row per posted quality control check line with the fields of its posted check repeated on each row. The page loads the period set in the new QC Analysis Default Window field on the Quality Control Setup page, or the last 90 days when the field is empty, and the Set Period action group reloads the page for the last 30 days, the last 90 days, the last 12 months, all history, or a custom start date. Turning on the Analyze toggle opens analysis mode for filtering, sorting, grouping, pivoting, and saving named analysis tabs, and requires the DATA ANALYSIS - EXEC permission set. Target values are shown on this page even when the target blind option is set on the plan line, so access is controlled through the quality control permission sets. For more information, see Analyze posted quality control data.

Enhancements/Modifications

With this release of the Aptean Quality Control (BC) extension, the number of decimal places shown for quality control values is set by the new Decimal Places field on the Quality Control Setup page instead of the Amount Decimal Places field on the General Ledger Setup page. The setting applies to answers and target values on quality control plans, quality control checks, and their target and answer FactBoxes, while posted quality control checks keep the values exactly as they were displayed at posting. When the Decimal Places field value is changed, a confirmation shows the number of lines to update and offers to reformat the values on existing plans and open checks, and the new Update Decimal Display action runs the same update later. Stored values and pass, warning, and fail results are not affected, and answers entered in the Quality Control App are stored with up to five decimal places. On upgrade, the field is set from the current Amount Decimal Places field value so that the display does not change. For more information, see Set up quality control.

Extension dependencies

The following extensions have been updated in this release to support the new or enhanced features:

Extension NameMinimum version requirementExtended functionality
Aptean Status Management2603.0.0.0Lists the statuses a quality control check can move to, and checks permission roles and mandatory statuses for the Change Status button in the Quality Control App.
Aptean Status Management Integration Layer2603.0.0.0Passes the available statuses and permission checks between the Aptean Quality Control (BC) and Aptean Status Management extensions.

UI/UX changes

The following UI/UX changes have been made in this release.

  • The Quality Control Data Analysis page has been added.

Quality Control Setup page

  • The Update Decimal Display action has been added to the Quality Control Setup page.
  • The Display Settings FastTab has been added to the Quality Control Setup page.
  • The QC Analysis Default Window field has been added to the Quality Control Setup page.
  • The Decimal Places field has been added to the Quality Control Setup page.

Quality Control App

  • The Change Status button has been added to the quality control check page in the Quality Control App.
  • The Change Status dialog has been added to the Quality Control App.

Resolved issues

The following issues have been resolved in this release.

IDDescription
380084The system does not show the number of quality control checks and posted quality control checks for the traced lot in the Quality Control FactBox on the Item Tracing page; both counts show 0 even when checks exist for the lot.
389071The system does not limit the Quality Control and Posted Quality Control Checks FactBoxes on the Lot No. Information Card and Lot No. Information List pages to the item of the lot; the counts and drill-down lists also include quality control checks for other items that use the same lot number.
390994The system does not open a quality control check promptly when navigating from the Aptean Shop Floor Production extension to the Quality Control App; every open quality control check is loaded before the work center and production order filter is applied, so the delay grows with the number of open checks.
394077The system intermittently fails to open the requested quality control check when another extension opens it in the Quality Control App, and shows the list of quality control checks instead.
384730The system creates a duplicate quality control check, or assigns the wrong lot number to a check, when production output is posted and the same Document No. is used on output journal lines in different journal batches or for different production orders.
393442The system creates duplicate quality control checks for the same work center or machine center when output is posted for a production order whose routing includes multiple work centers or machine centers, even though the Allow Multiple Open Checks field is cleared on the quality control trigger.