What's new in version 2603.0.354666.0

Warehouse Management System  •  Release Note  •  11/3/2026  • 

The minimum version required for the Aptean WMS app to operate with this release is 1.16.352759.0.

Resolved issues

The following issue has been resolved in this release.

IDDescription
401396The system stops the Create Pick action, or the creation of another warehouse document, with a deadlock message when two users create warehouse documents at the same time, even for different source documents. After the warehouse document was created, the system read the WMS activities of its source document in the order of the activity number, so it also locked the new activities of other users. The system also updated the WMS activity of a warehouse document every time the warehouse document header was changed, even when the date, assigned user and search text of the activity were unchanged, which caused extra waiting time on the scanner and in posting. The system now reads only the WMS activities of the source document, and updates a WMS activity only when one of these values has changed.